Cardiac Direct


x
x

Medical 247 BP Device with Temperature and SPO2 Pulse Oximeter

SunTech 247 Diagnostic Station

Features:

  • Adult & Large Adult All Purpose Cuffs
  • 8" blood pressure hose
  • Mains/Power Supply
  • Mains/Power Cable
  • Resource CD
  • Quick Start Guide
  • Reference Card


Designed with the idea that no two patients are alike, the SunTech 247 Diagnostic Station is the first clinical grade automated blood pressure device to offer a manual back-up mode. By combining the best of our 20 years of blood pressure research and technology with the capability to apply traditional methods of blood pressure measurement, the SunTech 247 provides the most reliable means of capturing blood pressure data.

Easily capture automated blood pressure measurements at the touch of a button or choose to measure with your stethoscope by using the manual feature for your patients with arrhythmias or other complex needs. We recognize that all patients are different. Now, everything you need for accurate blood pressure is in one intuitive device. With 10 available All-Purpose cuff sizes, ranging from child to thigh, the SunTech 247 caters to all of your patients

Automated Temperature Readings

With connect-and-go capability, adding temperature is effortless. The temperature module allows both oral/axillary and rectal readings with corresponding color-coded probe wells for storage.

Simply remove the plastic end-cap on the top of your SunTech 247 BP module and slide the temperature module until it snaps into place. The temperature module is ready to use instantly.

What's included:
  • Oral/Axillary probe (blue)
  • 1 box of FILAC FASTEMP probe covers
  • Other accessories
SpO2 Readings in an Instant

Our SpO2 add-on module includes industry-leading Nellcor compatible technology for easy-to-integrate pulse oximetry measurement. The SunTech 247 SpO2 module comes with a finger clip sensor that can be reused for multiple readings.

Simply remove the plastic end-cap on the bottom of your SunTech 247 BP module and slide the SpO2 module until it snaps into place. The SpO2 module is ready to use instantly.

What's included:
  • Reusable Adult Finger Sensor
  • 6" Extension Cable
  • Other accessories

Download Brochures


Technical Specifications:

  • Patient population: Adult and pediatric patients (age 3 and above
  • Method of measurement: Oscillometric
  • Initial inflation pressure: 160mmHg +/- 20mmHg
  • Blood pressure range (mmHg): 60 < Systolic BP < 270, 30 < Diastolic BP < 170
  • Blood pressure accuracy: Measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers
  • Blood pressure determination time: 35-40 seconds typical for Adult cuff
  • Heart rate range: 30-200 bpm +/- 2% or +/- 3 bpm, whichever is greater
  • Functional oxygen saturation range: 40-100%
  • Functional oxygen saturation accuracy: 70-100% +/- 2 digits (Note: because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of pulse oximeter equipment measurements can be expected to fall within +/- 2 digits of the value measured by a CO-oximeter.)
  • Power: External power supply for non-battery version: Globtek model: GTM21089-1506-T3 (SunTech part number: 19-0013-00) External power supply for Battery version, rechargeable by Globtek model: GTM21089-1509-T3 (SunTech part number 19-0014-00)
  • Calibration: Check once per year for BP and Temperature
  • Safety systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 330 mmHg. Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
  • Dimensions: Length = 5.5 inches, Height = 11.5 inches, Width = 3.8 inches; Length =14.0 cm, Height = 29.2 cm, Width = 9.7 cm
  • Standards: UL60601-1, CAN/CSA C22.2 601-1 IEC 60601-1, IEC 60601-1-2 (EMC), IEC 60601-1-4, ISO 9919, AAMI SP10:2002, ASTM E 1112, EN 12470-3 Meets Non-invasive Sphygmomanometers - General Requirements & Supplementary Requirements for Electro-Mechanical BP Measuring Systems, EN 1060-1, EN 1060-3

Maximum Protection Dental Guard Hello World

Maximum Protection Dental Guard promo video

Write a review

Maximum Protection Dental Guard

Maximum Protection Dental Guard

Yep! You are in the right place and don’t waste your precious time on hesitations. Our goal is to help those who care about people’s health. We care about the quality of our goods and there is no doubt about its highest level. Our vendors and manufacturers guarantee the premium quality of our products.